COST EVALUATION FOR 12-STOREY REINFORCED CONCRETE APARTMENT BUILDING IN SABAH DUE TO SEISMIC DESIGN

Authors

  • N. S. Zulkhibri
  • H. A. Roslan
  • M. I. Adiyanto Universiti Malaysia Pahang

Abstract


In June 2015, Ranau stated earthquake of moment magnitude M W 6.1 which cause a lot of damage to buildings. Therefore, seismic design input should be applied for new buildings to minimize the damage. This work investigates the influence of seismic design on structural works cost. A 12-storey apartment reinforced concrete apartment has been used as a model for the project. In this research, soil type D and 3 levels of seismicity were used as design variables. The reference peak ground acceleration, αgR used were 0.08g, 0.12g and 0.16g. The results indicate that models with seismic design have greater structural costs by increasing from 3.4% to 19.1%.

Downloads

Published

2023-06-30

How to Cite

N. S. Zulkhibri, H. A. Roslan, & M. I. Adiyanto. (2023). COST EVALUATION FOR 12-STOREY REINFORCED CONCRETE APARTMENT BUILDING IN SABAH DUE TO SEISMIC DESIGN. Journal of Engineering and Technology (JET), 14(1), 1–10. Retrieved from https://jet.utem.edu.my/jet/article/view/6400